Author: Aqil Jauhar
Protocol Structure
Neck Routine
- Topogram
- Non contrast
- Contrast
- Neck IV
Topogram
From middle of frontal sinus until T4 spine
![](https://knowledgebase.askradiographer.com/wp-content/uploads/2021/06/topogram-lateral-neck-with-topo-line.jpg)
Non Contrast
- Plan the ROI using lateral view of the neck
- Adjust ROI to align with cervical spine
![](https://knowledgebase.askradiographer.com/wp-content/uploads/2021/06/topogram-lateral-neck-with-topo-line.jpg)
Reconstruction Non Contrast
[table id=6 /]
Injector Setting
NP Test
Flow rate: 3.0 ml/s
Volume: 15 ml
Contrast
Non- Ionic Iodinated Contrast Media 300 mg I/ml Solution for injection/infusion
Flow rate: 3.0 ml/sec
Volume: 70 ml
Delay time to scan after contrast injection : 50s
Reconstruction Contrast
[table id=7 /]
Multi Planar Reconstruction (MPR)
Parallel Ranges:
Image thickness : 3.0mm
Number of images : 19
Neck IV:
Coronal – plan on sagittal image
(locate pathology if available)
Sagittal – plan on coronal image
Series of Images Send to PACS
- Topogram 0.6 T20f
- Neck 5.0 B31s
- Neck 1.0 B20s
- Neck IV 5.0 B31s
- Neck IV 1.0 B20s
- Patient protocol
- SAG NECK IV
- COR NECK IV
Leave A Comment?