Author: Aqil Jauhar
Protocol Structure
Head Routine
- Topogram
- Non contrast
- Contrast
- Head IV
Topogram
Topogram should be cover from vertex of skull to C1

Non Contrast
Adjust the ROI angle to align with Base of Skull
To reduce or avoid ocular lens exposure, the scan angle should be parallel to a line created by the supraorbital ridge and the inner table of the posterior margin of the foramen magnum

Reconstruction Non Contrast
[table id=4 /]
Contrast
Non- Ionic Iodinated Contrast Media 300 mg I/ml Solution for injection/infusion
Injector Setting
Inject using hand bolus method through the IV line
Reconstruction Contrast
[table id=5 /]
Multi Planar Reconstruction (MPR)
If the reconstruction already symmetrical, no need to do another axial plane.
Series of Images Send to PACS
- Topogram 0.6 T20f
- Head 5.0 H31s
- Head 1.0 H31s
- Head 5.0 H60s
- Head 1.0 H60s
- Head IV 5.0 H31s
- Head IV 1.0 H31s
- Patient protocol