CT ABDOMEN WITH CONTRAST

Author: Aqil Jauhar


Protocol Structure

Abdo Pelvis

  • Topogram
  • Non contrast
  • Contrast
  • Abdomen IV

Topogram

From above the diaphragm until below of symphysis  pubis


Non Contrast

Vertically: from above the diaphragm until below of symphysis pubis

Horizontal: include bilateral abdominal soft tissue


Reconstruction Non Contrast

[table id=12 /]

Injector Setting

NP Test
Flow rate: 3.0 ml/s
Volume: 15 ml

Contrast

Non- Ionic Iodinated Contrast Media 300 mg I/ml Solution for injection/infusion
Flow rate: 3.0 ml/sec
Volume: 100 ml


Reconstruction Contrast

[table id=13 /]

Multi Planar Reconstruction (MPR)

Coronal abdomen post contrast

Series of Images Send to PACS

  1. Topogram 0.6 T20f
  2. AbdoPelvis 5.0 B30f
  3. AbdoPelvis 1.0 B20f
  4. AbdoPelvis IV 5.0 B30f
  5. AbdoPelvis IV 1.0 B20f
  6. Patient protocol
  7. COR ABD IV

Was this article helpful?

Related Articles