Author: Aqil Jauhar
Protocol Structure
Abdo Pelvis
- Topogram
- Non contrast
- Contrast
- Abdomen IV
Topogram
From above the diaphragm until below of symphysis pubis

Non Contrast
Vertically: from above the diaphragm until below of symphysis pubis
Horizontal: include bilateral abdominal soft tissue

Reconstruction Non Contrast
[table id=12 /]
Injector Setting
NP Test
Flow rate: 3.0 ml/s
Volume: 15 ml
Contrast
Non- Ionic Iodinated Contrast Media 300 mg I/ml Solution for injection/infusion
Flow rate: 3.0 ml/sec
Volume: 100 ml
Reconstruction Contrast
[table id=13 /]
Multi Planar Reconstruction (MPR)
Coronal abdomen post contrast
Series of Images Send to PACS
- Topogram 0.6 T20f
- AbdoPelvis 5.0 B30f
- AbdoPelvis 1.0 B20f
- AbdoPelvis IV 5.0 B30f
- AbdoPelvis IV 1.0 B20f
- Patient protocol
- COR ABD IV